DRI home

  icon-r01.gif (2255 bytes)icon-r02.gif (2403 bytes)icon-r03.gif (2288 bytes)icon-r04.gif (2254 bytes)

 


Specification

Model

SP-M1

Syringe Size

10 ul – 1000 ul

Power Requirement

AC110V-220V50Hz /60Hz orDC12V

Pusher Advance Per Micro Step

0.08 um

Volume Per Micro Step

132.4 nl with Unimetrics 1000ul syringe, ID4.61mm

Minimum Flow Rate

132.4 nl / min using Unimetrics 1000ul syringe, ID4.61mm

Maximum Flow Rate

1.324 ml / min using Unimetrics 1000ul syringe, ID4.61mm

Linear Travel Rate

Minimum: 7.94um/min  Maximum: 79.4mm/min

Accuracy

0.5%  (single infusion volume>30% total infusion volume )

Dimension

Controller: 17.5 x 10.5 x 6.5 cm (LWH)

Driver: 17.5 x 4.5 x 5 cm (LWH)

User defined syringe ID

0.01 mm-4.0 mm

 

Flow Rate

Syringe (Unimetrics)

Diameter

Minimum

Maximum

10 ul

0.46mm

1.32 nl/min

13.19 ul/min

25 ul

0.73mm

3.32 nl/min

33.2 ul/min

50ul

1.03mm

6.61 nl/min

66.1 ul/min

100ul

1.46mm

13.28 nl/min

132.8 ul/min

250ul

2.30mm

32.97 nl/min

329.7 ul/min

500ul

3.26mm

66.25 nl/min

662.5 ul/min

1000ul

4.61mm

132.4 nl/min

1324 ul/min

 

 

 

Specification

Model

SP-M2

Syringe Size

1000 ul – 60ml

Power Requirement

AC110V-220V50Hz /60Hz orDC12V

Pusher Advance Per Micro Step

0.08 um Per Micro Step

Volume Per Micro Step

1Micro Step =4.411ul

Minimum Flow Rate

4.411ul / min using BectonDickinson 60ml syringe

Maximum Flow Rate

44.11 ml / min using BectonDickinson 60ml syringe, ID26.60mm

Linear Travel Rate

Minimum: 7.9um/min  Maximum: 79.4mm/min

Accuracy

0.5%  (single infusion volume>30% total infusion volume )

Dimension

Controller: 17.5 x 10.5 x 6.5 cm (LWH)

Driver: 24.5 x 10.0 x9. 5 cm (LWH)

User defined syringe ID

0.01 mm-40 mm

 

Flow Rate

Syringe (Unimetrics)

Diameter /mm

Maximum ml/min

Minimum nl/min

1ml

4.7

1.377

137.7

3ml

8.59

4.6

460.0

5ml

11.99

8.96

896.2

10ml

14.48

13.07

1307

20ml

19.05

22.62

2262

30ml

21.59

29.05

2905

60ml

26.60

44.11

4411

 

Specification

Model

SP-M3

Syringe Size

1000 ul – 60ml

Power Requirement

AC110V-220V50Hz /60Hz orDC12V

Pusher Advance Per Micro Step

0.08 um Per Micro Step

Volume Per Micro Step

1Micro Step =4.411ul

Minimum Flow Rate

4.411ul / min using BectonDickinson 60ml syringe

Maximum Flow Rate

44.11 ml / min using BectonDickinson 60ml syringe, ID26.60mm

Linear Travel Rate

Minimum: 7.9um/min  Maximum: 79.4mm/min

Accuracy

0.5%  (single infusion volume>30% total infusion volume )

Dimension

Controller: 17.5 x 10.5 x 6.5 cm (LWH)

Driver: 24.5 x 10.0 x9. 5 cm (LWH)

User defined syringe ID

0.01 mm-40 mm

 

Flow Rate

Syringe (Unimetrics)

Diameter /mm

Maximum ml/min

Minimum nl/min

1ml

4.7

1.377

137.7

3ml

8.59

4.6

460.0

5ml

11.99

8.96

896.2

10ml

14.48

13.07

1307

20ml

19.05

22.62

2262

30ml

21.59

29.05

2905

60ml

26.60

44.11

4411